 FBO Series
Mass flow sensors for gases
FEATURES * Ranges 0...30 to 0...1000 or -600...1000 sccm1 * Bidirectional sensing * Actual mass flow sensing * Sensortechnics PRO services
MEDIA COMPATIBILITY
To be used with dry gases only The FBO series is NOT designed for liquid flow and will be damaged by liquid flow through the sensor
SPECIFICATIONS
Maximum ratings Supply voltage2 8 to 15 V typ. 10 0.01 V max. 50 mW typ. 30 mW
ELECTRICAL CONNECTION
Power consumption
P1
P2
Temperature limits Operating Storage Mechanical shock
-25 to 85C -40 to 90C 100 g (5 drops, 6 axes)
123456
Note: 1 sccm denotes standard cubic centimeters per minute 2 Output voltage is ratiometric to supply voltage
E / 11721 / A
1/6
www.sensortechnics.com
FBO Series
Mass flow sensors for gases
FLOW SENSOR CHARACTERISTICS3
(VS = 10 0.01 V, TA = 25C)
Part no.
FBOM200DB FBOM030DB FBOL001DB FBOL001DBX
Flow range (full scale)
200 sccm 30 sccm 1000 sccm -600...1000 sccm
Max. flow change4
5.0 l/sec 5.0 l/sec 5.0 l/sec 5.0 l/sec
Output voltage @ trim point
30 mV @ 100 sccm 11.8 mV @ 25 sccm 50 mV @ 650 sccm 50 mV @ 650 sccm
PERFORMANCE CHARACTERISTICS
(VS = 10 0.01 V, TA = 25C)
Characteristics
Zero offset Repeatability and hysteresis (combined) Offset Temperature effects Span FBOL001DB all others -25 to 85 C5 -25 to 25 C FBOM200DB FBOM030DB FBOL001DB FBOL001DBX 25 to 85 C FBOM200DB FBOM030DB FBOL001DB FBOL001DBX Sensor resistance (Pin 2 - Pin 1, Pin 6 - Pin 1) Sensor current (Pin 2 - Pin 1, Pin 6 - Pin 1) Response time Common mode pressure
Min.
-1.0
Typ.
0
Max.
1.0 1.0 0.35
Unit
mV % reading mV
0.20 2.5 5.0 5.0 5.0 -2.5 -5.0 -5.0 -5.0 5 0.6 1.0 3.0 25
% reading
kOhm mA ms p si
Notes: 3 A 5 micron filter is recommended for all devices. 4 Maximum allowable rate of flow change to prevent damage. 5 Shift is relative to 25 C.
E / 11721 / A
2/6
www.sensortechnics.com
FBO Series
Mass flow sensors for gases
FLOW SPECIFICATIONS
(VS = 10 0.01 V, TA = 25C)
FBOM200DB
Press. Flow (mbar) (sccm)6 0.49 0.35 0.21 0.09 0.00 0.00 -0.21 -0.35 -0.49 200 150 100 50 0 50 -100 -150 -200
FBOM030DB
FBOL001DB
FBOL001DBX
Nom. Tol. (mV) ( mV) 55.50 52.90 50.00 42.50 29.20 0.00 -28.90 -41.20 -48.20 7.0 6.0 5.0 6.0 5.0 1.5 15.0 26.0 30.0
Nom. Tol. Press. Flow Nom. Tol. Press. Flow (mV) ( mV) (bar) (sccm)6 (mV) ( mV) (mbar) (sccm)6 44.50 38.75 30.00 16.50 0.00 16.50 -30.00 -38.80 -44.50 4.25 3.00 1.50 2.50 1.00 4.50 5.00 7.65 9.75 53 36 17 9.8 7.4 6.2 5 2.5 0 -9.8 -53 30 20 10 5 4 3 2 1 0 -5 -30 14.0 9.5 5.0 2.5 2.0 1.5 1.0 0.5 0.0 -2.5 -14.0 2.5 1.5 1.5 1.0 1.0 1.0 1.0 0.8 0.6 2.0 5.0 3.4 2.4 1.8 0.83 0.31 0 -0.31 -0.83 -1.6 -2.4 -3.4 1000 800 650 400 200 0 -200 -400 -600 -800 -1000
Nom. Tol. Press. Flow (mV) ( mV) (mbar) (sccm)6 55.50 52.90 50.00 42.50 29.20 0.00 -28.90 -41.20 -48.20 -52.20 -55.00 3.70 3.50 2.50 3.00 3.20 1.00 15.00 26.00 29.50 32.50 36.00 3.4 2.4 1.8 0.83 0.31 0 -0.31 -0.83 -1.6 1000 800 650 400 200 0 -200 -400 -600
Note:
6
Devices are calibrated in mass flow. Tolerance values apply to calibration type only.
OUTPUT VS. FLOW CURVES
FBOM200DB FBOM030DB
FBOL001DB
FBOL001DBX
E / 11721 / A
3/6
www.sensortechnics.com
FBO Series
Mass flow sensors for gases
HEATER CONTROL CIRCUIT
SENSING BRIDGE SUPPLY CIRCUIT
Note: These circuits are required for operation per specifications. Circuits are not on board the sensor.
DIFFERENTIAL INSTRUMENTATION AMPLIFIER CIRCUIT (optional)
2 R + R1 R4 (V2 - V1 ) + VOffset VO = 2 R R 1 3 R6 where VOffset = VS R +R 5 6
E / 11721 / A
4/6
www.sensortechnics.com
FBO Series
Mass flow sensors for gases
OUTLINE DRAWING
7.60 (0.30) 2.8 (0.11) 2.9 (0.114) 1.40 (0.055) 6.3 (0.25) 1.8 (0.07) 5.1 (0.20)
54.4 (2.14) 8.3 (0.325) 8.4 (0.33)
P1
P2
31.5 (1.24) 23.6 (0.93) 2.8 (0.11)
1.0 (0.04) 5.1 (0.20) 7.4 (0.29) 12.7 (0.50) 15.5 (0.61)
123456
0.6 (0.025) 1.52 (0.06)
2.5 (0.10)
4.1 (0.16)
23.9 (0.94) 30.5 (1.20)
third angle projection mass: approx. 10.8 g dimensions in mm (inches)
Note: Positiv flow direction is defined as proceeding from port 1 (P1) to port 2 (P2) and results in positive output (pin 6 > pin 2). Negative flow direction is defined conversely and results in negative output (pin 6 < pin 2).
E / 11721 / A
5/6
www.sensortechnics.com
FBO Series
Mass flow sensors for gases
GAS CORRECTION FACTORS7
Gas type Helium (He) Hydrogen (H2) Argon (Ar) Nitrogen (N2) Oxygen (O2) Ai r Nitric oxide (NO) Carbon monoxide (CO) Methane (CH4) Ammonia (NH3) Nitrous oxide (N2O) Nitrogen dioxide (NO2) Carbon dioxide (CO2) Correction factor (approx.) 0.58 0.78,9 0.95 1.0 1.0 1.0 1.0 1.0 1.1 1.1 1.35 1.35 1.35
Notes: 7 Gas correction factors are referenced to nitrogen (N2) as calibration gas type. Approximate gas correction factors are provided as guidelines only. Individual gas types may perform differently at temperature extremes and varying flow rates. 8 When sensing Hydrogen (H2) or Helium (He) it may be necessary to power the mass flow sensor using increased supply voltage: Hydrogen typ. 12 V, Helium typ. 15 V 9 Hydrogen (H2) flow measurement requires the use of a special sensor. These devices provide normal operation when sensing hydrogen flow and are designated with an "H" at the end of the order number.
ORDERING INFORMATION - AVAILABLE LISTINGS
Note: Preferred listings are highlighted in grey
Flow range
30 sccm 200 sccm 1000 sccm -600...1000 sccm
Dry gas
FBOM030DB FBOM200DB FBOL001DB FBOL001DBX
Hydrogen gas9
--FBOM200HB FBOL001HB ---
Sensortechnics PRO services: * Extended guarantee period of 2 years * Improved performance characteristics * Custom product modifications and adaptations even for small quantities * Advanced logistics models for supply inventory and short delivery times * Technical support through application engineers on the phone or at your site * Fastest possible technical response for design and QA engineers ... plus other services on request
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. E / 11721 / A 6/6
www.sensortechnics.com


▲Up To Search▲   

 
Price & Availability of FBOL001DB

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X